WMI Namespace and Provider Errors

WMI Namespace and Provider Errors

Applicable WMI Error Codes

  • 0x8004100E - Invalid Namespace

Overview

This error occurs when the specified WMI namespace cannot be found or accessed during monitor addition or data collection. An incorrect namespace, a missing or unregistered WMI provider, or issues with the WMI repository may cause this.

Common Causes

  • Incorrect or unavailable WMI namespace.
  • Corrupted or damaged WMI repository or related WMI components.
  • Missing, unregistered, or incorrectly registered WMI provider.
  • Corrupted or missing MOF files.
  • The application or Windows feature providing the required WMI namespace is not installed or configured (for example, SQL Server, IIS, Cluster, or BitLocker).
  • Namespace mismatch caused by application version differences.
  • Incomplete application installation or upgrade.
  • Remote WMI connectivity issues that prevent successful access to the required namespace.

Resolution Steps

1. Validate the Namespace Using WBEMTEST
  1. Refer to the Namespace & WMI Class KB to identify the namespace and WMI class associated with the affected metric.

  2. Open WBEMTEST on the Applications Manager server and connect to the target server using the required namespace.

  3. Execute the corresponding WQL query.

  4. Refer to the Verify WMI Connectivity Using WBEMTEST section for detailed instructions.

NotesNote: If the namespace connection fails with error 0x8004100E, verify that the namespace exists on the target server and that the required WMI provider is installed and properly registered.

2. Rebuild WMI Repository
  1. Refer to the Reconstruct / Rebuild WMI Class KB for detailed instructions on repairing or rebuilding the WMI repository.
3. Re-register Application-Specific WMI Providers
  1. For application-specific namespaces such as Cluster services, verify that the required WMI provider is installed and properly registered. If required, re-register the provider and associated MOF files using the procedure recommended for that application or Windows feature.

Example for Cluster namespace:

Quote
regsvr32 -s C:\Windows\System32\wbem\ClusWMI.dll
mofcomp C:\Windows\System32\wbem\clusWMI.mof
4. Verify Firewall Configuration
If the namespace is available locally but cannot be accessed remotely from Applications Manager, verify the firewall and DCOM configuration. Ensure the following are allowed through Windows Firewall and network firewall:
  • TCP Port 135 (RPC Endpoint Mapper)
  • WMI service communication
  • Dynamic RPC Ports

Enable the firewall rules mentioned in the "The RPC server is unavailable" KB.

5. Restart the WMI Service
  1. Run the following commands on the target server:
Quote
net stop winmgmt /y
net start winmgmt

InfoContact Support

When contacting support, provide the following:

  • Screenshots of the relevant troubleshooting steps performed and their results.
  • Screenshot of the WBEMTEST error message or result.
  • Validate the WMI connection using both the target server's hostname and IP address, and identify which succeeds in your environment.
  • If only one method succeeds, update the monitor using the Update Hostname/IP option and verify whether the issue is resolved.
  • Enable Print all logs by navigating to Settings → Logging. Perform a manual poll for the affected Windows monitor.
  • Generate a Support Information File (SIF) from Applications Manager after reproducing the issue and performing a manual poll.

                    New to ADSelfService Plus?

                      • Related Articles

                      • WMI Query and Class Validation Errors

                        Applicable WMI Error Codes 0x80041017 - Invalid Query 0x80041010 - Invalid Class Overview This error occurs when the WMI query executed during monitor addition or data collection is invalid, references unavailable WMI classes or performance counters, ...
                      • WMI Error Troubleshooting Guide

                        This Knowledge Base provides troubleshooting guidance for commonly encountered Windows Management Instrumentation (WMI) errors that may occur while adding a Windows monitor or collecting metrics using WMI mode in Applications Manager. WMI errors can ...
                      • "Authentication Failed or Access denied" message is shown, when trying to add the Server Monitor through WMI mode.

                        Overview This article provides troubleshooting steps for Authentication Failed, Access Denied, and related WMI authentication errors encountered while adding a Windows Server Monitor or during data collection through WMI mode in Applications Manager. ...
                      • WMI/RPC Communication Errors

                        Applicable WMI Error Codes 0x800706BE – The remote procedure call failed 0x80010002 – Call was canceled by the message filter Overview These errors occur when Applications Manager is unable to establish or maintain WMI/RPC communication with the ...
                      • Configuring non-admin user account for WMI monitoring

                        By default, Windows allows only members of the Administrators or Domain Admin groups to read WMI class information. However, you can configure a regular user to access WMI information by performing the following steps on the server that needs to be ...