Unable to update SNMP or Manually Edit Interface details Error : "Value could not be updated"

Unable to update SNMP or Manually Edit Interface details Error : "Value could not be updated"

Issue: Unable to update the SNMP or Manually Edit the Interface parameters for any interface and getting error "Value could not be updated"

Please follow the below steps and check on the issue:

1. Open the NetFlow Analyzer web GUI.

2. Change the URL to  http://localhost:8080/netflow/jspui/runQuery.jsp ; where 8080 is the web server port used in your setup.

3. In the box for executing the query, type the following and click on 'Execute Query'.

update NetFlow_Interface set MEDIA_STATE=2

4. Once the query has been executed, Restart the NetFlow Analyzer Service and Check the Issue.
                  New to ADManager Plus?