FIX for NFA-10250 for ASA issue and OUT traffic not shown for devices

FIX for NFA-10250 for ASA issue and OUT traffic not shown for devices

This Patch is applicable only over the NetFlow Analyzer build 10250

Please download and unzip the patch file from the below link:

https://uploads.zohocorp.com/Internal_Useruploads/dnd/NetFlow_Analyzer/o_19uprk25h3r21ci71tru24t1ule1/Fix.zip

It contains 3 files named NetFlowCollector.jar, NetFlowClient.jar and netflow.war

Steps:

1. Stop the NetFlow Analyzer service.
2. Cut and copy the existing NetFlowCollector.jar and
NetFlowClient.jar from NetFlow_Home/lib to safe location outside the ManageEngine directory.
3. Cut and copy the existing netflow.war from NetFlow_Home/webapps to safe location outside the ManageEngine directory.
4. Copy the downloaded NetFlowCollector.jar,
NetFlowClient.jar and netflow.war in the respective locations.
5. Open command prompt as Administrator and navigate to NetFlow_Home/troubleshooting
6. Execute rawCleanup.bat and wait for it to complete.
7. Delete the folder named neflow under NetFlow_Home/webapps.
8. Start the NetFlow Analyzer service and check on the issue.
                  New to ADManager Plus?

                    New to ADSelfService Plus?

                      • Related Articles

                      • NCM/NFA 12100 Consolidated Fix

                        Note: This is applicable only for NCM/NFA/FWA Build 12100. Make sure to take the backup of the installation before applying the patch. Patch: 1. Stop NCM(OpManager) Service. 2. Download the patch file from the link here 3. Copy and extract (using ...
                      • Incorrect traffic information in Netflow analyzer

                        NetFlow Analyzer shows the information based on the flow Packets (NetFlow, sflow, Jflow, netstream etc..) exported by the device to the NetFlow Analyzer installed server. We have seen many customers come with the issue that the Utilization ...
                      • Fix for Cisco ASA showing 0.0.0.0.0.0 for source and Destination for build 9900

                        Thank you for your time during the call. Please follow the below steps and check on the issue: 1) Stop the NetFlow Analyzer Service. 2) Open Command prompt as administrator and navigate to NetFlow_Home/bin and execute startDB.bat two times for ...
                      • Adding devices in Network Configuration Manager

                                                         In this video you will learn how to add devices in Network Configuration Manager                                                                                   
                      • IPGroup OUT Traffic Fix for Build 11000

                        This Patch is applicable only over the NetFlow Analyzer build 11000 Please download the patched files from the below link: https://uploads.zohocorp.com/Internal_Useruploads/dnd/NetFlow_Analyzer/o_19kh3tk7i18bk1prm1odpffd1mq81/11000_ConsPat_04_23.zip ...