Upgrade failure from 10500 to 10512.

Upgrade failure from 10500 to 10512.

Exception missing file 
HelpDesk/ServiceDeskplus-MSP/tools/postgres/bin/gettimezone: not found

The upgrade failed because of a missing file Gettimezone.

Please navigate to the application folder ManageEngine/ServiceDeskPlus-MSP/tools/postgres/bin

Check if there is a file called Gettimezone 

If the file is already available in the above folder please follow these steps

1.  Stop the Manageengine ServiceDesk Plus-MSP application
2. Go to the directory ../ManageEngine/ServiceDeskplus-MSP/tools/postgres/bin. Move the existing 'gettimezone' file to a different location outside ManageEngine installation directory.
3. Rename the 'gettimezone_64' as 'gettimezone'.
4. Initiate the upgrade. This should do it.

                  New to ADSelfService Plus?

                    • Related Articles

                    • 10.5 Linux Upgrade failure and solutions

                      Traces in logs : 1. java.lang.Exception: InitPgsqlScript exited with value :: 1 at com.adventnet.persistence.PostgresPreProcessor.executeInitPgsqlScript(PostgresPreProcessor.java:1733) 2. PGSQL Permission related errors. 3. SDP MSP installed as root ...
                    • Steps to revert the environment from an upgrade failure situation ?

                      1. Rename the failed set up installation folder to <supportcenter_old> . Don't delete the installation folder until the process is completed. Download the existing version which you had before this upgrade from the below archives link. ...
                    • Upgrade failure from 1420X to 14300.

                      Error trace: 5 Sep, 2023 6:08:56 PM [com.adventnet.tools.update.installer.Unzipper] [INFO] : lib/phantomjs/linphantomjs/phantomjs 25 Sep, 2023 6:08:56 PM [com.adventnet.tools.update.installer.Unzipper] [SEVERE] : ERR:Exception while writing ...
                    • Upgrade failure to 10500 - Linux platforms

                      You may experience an upgrade failure in linux platforms when upgrading to 10500. Here are the traces from logs, Feb 21, 2020 4:55:03 PM  [com.adventnet.tools.update.installer.Unzipper]  [SEVERE] : ERRUnexpected Error. Please click View Log>> for ...
                    • 11.0 Upgrade failure Inputs needed for analysis

                      To analyze Supportcenter plus upgrade failure cases (Upgrade from 8121 - to 11.0 version), we need following types of logs. 1) If upgrade itself got failed -> need SCP\server\default\log for analysis 2) After upgrade, if the product does not start, ...