Alarms for "Data Not Collected" monitors
1.Please edit the NmsProcessesBE.conf file in OpManager\conf folder and search for the text CLEAN_DATA_INTERVAL 999999 .
2.Paste GENERATE_DATACOLL_EVENT true right after that.
For example :
CLEAN_DATA_INTERVAL 999999 GENERATE_DATACOLL_EVENT true
3.Save this file and restart OpManager service.
Disclaimer: There is no option to choose the devices and it will send alarms even for the wrong monitors. So there is a chance of alarm flooding. If you are not interested, it should be updated as false
|
New to ADSelfService Plus?
Related Articles
Escalating alarms in OpManager
Difference between SNMP monitors and Traps
S.No SNMP Monitors Traps 1 Pull Model: OpManager sends SNMP request to the SNMP agent running on the monitored device and receives the response. Push Model: Monitored device(SNMP agent) sends messages in the form of traps to the trap ...
Performance Data Archiving
Which are the database tables to be queried for performance data? Here are the details that might help you extract reports by connecting to the database: 1. The resources polled for data collection are stored in the table polleddata, and each polled ...
AD Monitors Shows N/A in OpManager
This problem could due to the following reasons: 1)WMI is not configured properly in OpManager (OpManager uses WMI credential to monitor AD servers). 2)Required Monitors are not associated to the device in OpManager. 3)WMI might not be responding to ...
No Database listed while adding MSSQL Monitors
Issue/Scenario: When I try to add MSSQL performance Monitors, I get to the stage to add databases but there were no databases listed . This issue could occur if 32bit MSSQL is installed on a 64bit Widows2008 R2. Solution/Workaround: Apparently ...